NOTE 1 Volatile organic substances include the low molecular weight substances in mixtures such as mineral oil.
NOTE 2 It is not always possible to adjust test conditions simultaneously for inorganic and organic substances. Test conditions can also vary between different groups of organic substances. Test conditions for organic substances are generally more stringent than those for inorganic substances. The test conditions are generally described in a way that they fit testing organic substances and are also applicable to inorganic substances depending on the set-up.
NOTE 3 For ecotoxicity testing, eluates representing the release of both inorganic and organic substances are needed. In this document, ecotoxicological testing is meant to include also genotoxicological testing.
NOTE 4 Granular solid waste materials with a low hydraulic conductivity that can cause detrimental pressure build-up are not supposed to be subjected to this test.
NOTE 5 This procedure is generally not applicable to solids that are easily biologically degradable and solids reacting with the leachant, leading to, for example, excessive gas emission or excessive heat release, impermeable hydraulically bound solids or solids that swell in contact with water.
NOTE 6 Granular solid waste materials without potential for beneficial use can be materials with gas generation or biodegradation during a potential reuse scenario.
NOTE 7 If a leaching test according to EN 16637‑3 has been performed, additional EN 17516 testing does not need to be carried out.
NOTE 8 The relative standard deviations for inorganic and organic substances are relatively high which is due to low concentration levels in the eluates (see Annex F).
EN 17516