1 Scope
This part of ISO 10077 specifies a method and gives reference input data for the calculation of the thermal
transmittance of frame profiles and of the linear thermal transmittance of their junction
with glazing or opaque panels.
The method can also be used to evaluate the thermal resistance of shutter profiles
and the thermal characteristics of roller shutter boxes and similar components (e.g.
blinds).
This part of ISO 10077 also gives criteria for the validation of numerical methods used for the calculation.
This part of ISO 10077 does not include effects of solar radiation, heat transfer caused by air leakage
or three-dimensional heat transfer such as pin point metallic connections. Thermal
bridge effects between the frame and the building structure are not included.