BS EN 16382 is the European standard on thermal insulating materials and products used in buildings to reduce energy consumption in buildings by preventing heat gain or loss through the building envelope.
BS EN 16382 specifies equipment and procedures for determining the pull-through resistance of plate anchors through thermal insulation products.
BS EN 16382 on thermal insulating materials and products is useful for:
The pull-through resistance of a plate anchor through thermal insulation products is determined by a direct tensile load perpendicular to the surface of the thermal insulation product.
BS EN 16382 guides you through the test apparatus requirements to test plate anchor pulled through the thermal insulation product giving the principle of the test arrangement.
BS EN 16382 shows up the schematic presentation of a failure with a breaking cone of the insulation product after pull-through testing.
The dimensions of the specimen of the thermal insulation product are described in BS EN 16382.
Arrangement of the thermal insulation product in the test setup and preparation of the test specimens are provided in BS EN 16382.
The test procedure and the attachment of the test specimen to the tensile testing machine are specified in BS EN 16382.
Calculation and expression of results and the test report of each series of pull-through resistance of plate anchors are set out in BS EN 16382.
Furthermore, BS EN 16382 guides you through the design and manufacture of insulation anchors, which are used for attaching insulation to a surface and available in many steel variations to ensure your insulation remains secure, efficient, and in place.
As a result, while designing high-energy performance structures, insulation anchor bolts with adhesion properties are critical to a building's thermal performance, which works for heating, ventilation, or air conditioning.
EN 16382:2016