IEC 60332-3-10 is a part of the IEC 60332 series on electric and optical fibre cables.
IEC 60332-3-10 provides details on the apparatus and its arrangement and calibration for methods of test for the assessment of the vertical flame spread of vertically mounted bunched wires or cables, electrical or optical, under defined conditions.
Note: For IEC 60332-3-10 the term “electric wire or cable” covers all insulated metallic conductor cables used for the conveyance of energy or signals.
IEC 60332-3-10 on tests on electric and optical fibre cables is useful for:
IEC 60332-3-10 defines the various categories and the relevant procedures for testing vertical flame spread of vertically-mounted bunched wires or cables. The categories are distinguished by test duration, the volume of non-metallic material of the test sample and the method of mounting the sample for the test. In all categories, cables having at least one conductor of cross-sectional area greater than 35 mm2 are tested in a spaced configuration, whereas cables of conductor cross-sectional area of 35 mm2 or smaller and optical fibre cables are tested in a touching configuration.
IEC 60332-3-10 specifies methods of test for flame spread characteristics for a single vertical insulated wire or cable.
IEC 60332-3-10 also covers the cable features as mentioned below:
IEC 60332-3-10 best practice guidelines help increase safety of optic fibres and cables.
BS EN IEC 60332-3-10:2018 supersedes BS EN 60332-3-10:2009. BS EN IEC 60332-3-10:2018 includes some technical changes concerning BS EN 60332-3-10:2009. These include:
IEC 60332-3-10:2018/COR1:2018
EN 55103-2:2009/IS1:2012
EN 60332-3-10 Ed 1.0 /A2
EN IEC 60332-3-10:2018
IEC 60332-3-10:2018
IEC 60332-3-10:2018