BS EN IEC 55016 is a series on specifications for radio disturbance and immunity measuring apparatus and methods. radio disturbance is a disturbance generated by an external source that affects an electrical circuit by electromagnetic induction, electrostatic coupling, or conduction. BS EN IEC 55016-1-1 specifies the characteristics and performance of equipment for the measurement of radio disturbance in the frequency range 9 kHz to 18 GHz. In addition, requirements are provided for specialized equipment for discontinuous disturbance measurements.
The specifications in BS EN IEC 55016-1-1 apply to electromagnetic interference (EMI) receivers and spectrum analyzers. The term “measuring receiver” used in BS EN IEC 55016-1-1 refers to both EMI receivers and spectrum analyzers. The calibration requirements for measuring receivers.
BS EN IEC 55016-1-1 on radio disturbance and immunity measuring apparatus is useful for:
The radio disturbance may degrade the performance of the circuit or even stop it from functioning. In the case of a data path, these effects can range from an increase in error rate to a total loss of the data. BS EN IEC 55016-1-1 describes the immunity measuring apparatus its testing and building specifications. BS EN IEC 55016-1-1 consists of measuring apparatus, coupling devices for conducted disturbance measurements, ancillary equipment – disturbance power antennas and test sites for radiated disturbance measurements, antenna calibration sites and reference test sites for 5 MHz to 18 GHz EMC antenna calibration to specify radio disturbance and immunity measuring apparatus and methods.
BS EN IEC 55016-1-1 discusses Spectrum analyzers and FFT-based measuring instruments that meet the requirements for the relevant detector or discontinuous disturbance analyzer (DDA) may be used for compliance measurements. For emission measurements, FFT-based measuring instruments sample and evaluate the signal continuously during the measurement time. BS EN IEC 55016-1-1 utilizes a “black-box” approach to determining equipment compliance to the standard. Equipment is determined to be compliant with BS EN IEC 55016-1-1 based only on meeting the stated performance requirements of BS EN IEC 55016-1-1. Using BS EN IEC 55016-1-1 you can specify the characteristics and performance of equipment for the measurement of radio disturbance in the frequency range 9 kHz to 18 GHz.
BS EN IEC 55016-1-1:2019 supersedes BS EN 55016-1-1:2010+A2:2014. BS EN IEC 55016-1-1:2019 includes some technical changes with respect to BS EN 55016-1-1:2010+A2:2014. These include:
CISPR 16-1-1:2019
EN 55016-1-1 Ed.4.0