1 Scope
This Standard specifies requirements for preparing and assembling parts to be joined
by wire wrapping, as well as the selection, calibration, use and certification of
wire wrapping tools.
The covered wire-wrapped connections are illustrated in .
This type of connection is similar to “Class A preferred” or “modified” connection
detailed in MIL-STD-1130, and NASA NHB 5300.4(3H).
Only previously tested and qualified wire-wrapped connections are covered by this
Standard, which includes four wire sizes from 24 AWG to 30 AWG, and three terminal
post sizes up to 1,78 mm maximum diagonal. A step-by step procedure is covered in
the informative Annex A.
The use of heavier gauge wire and larger terminals is not generally prohibited, but
it is considered unlikely that for such dimensions the method of wire-wrapping would
be chosen as the electrical interconnection technique. Instead it is assumed that
wire larger than 24 AWG will be multi-stranded and terminated by soldering in conformance
with ECSS-Q-ST-70-08, or by crimping in conformance with ECSS-Q-ST-70-26.
Training and certification requirements for operators and inspectors are defined in
clause 5.6.7 and in ECSS-Q-ST-20.
With effect from the date of approval, this Standard announces the adoption of the
external document on a restricted basis for use in the European Cooperation for Space
Standardization (ECSS) system.
This standard may be tailored for the specific characteristic and constraints of a
space project in conformance with ECSS-S-ST-00.
Figure 1-1
—
Single wire-wrapped connection to square terminal and reference corner
Shows either 3 or 4 corners of contact of insulation minimum ¾ turn of insulated wire