1 Scope
This European Standard describes a method to determine the aerobic biological activity
of growing media and soil improvers or constituents thereof by measuring the oxygen
uptake rate (OUR). The oxygen uptake rate is an indicator of the extent to which biodegradable
organic matter is being broken down within a specified time period. The method is
not suitable for material with a content of particle sizes > 10 mm exceeding 20 %.