Water Supply system
|
Operating range of shower hoses
|
Flow rates
|
|
|---|---|---|---|
|
Limits
|
Recommended
|
See Table 3
|
|
|
Type 1
see Figure 1
|
Dynamic Pressure
0,05 MPa to 0,5 MPa
0,5 bar to 5 bar
|
Dynamic Pressure
(0,1 to 0,3) MPa
(1,0 to 3,0) bar
|
Min. 0,42 l/s (25,2 l/min)
at 0,3 + 0,02 MPa (3 + 0,2 bar)
|
| Dynamic Pressure | Dynamic Pressure | Class E | |
| Type 2 |
(0,01 to 0,2) MPa
(0,1 to 2) bar
|
(0,02 to 0,10) MPa
(0,2 to 1,0) bar
|
0,06 l/s < Q < 0,18 l/s (3,6 l/min < Q < 10,8 l/min.)
at 0,01 MPa (0,1 bar)
|
| see Figure 2 | Class H | ||
| 0,18 l/s ≤ Q (10,8 l/min ≤ Q) at 0,01 MPa (0,1 bar) | |||
| Temperature | T ≤ 70°C | T ≤ 42°C | |

| 1 | Cold water |
| 2 | Hot Water |
| 3 | Mains supply pipe (Supply pressures up to 10 bar) |
| 4 | Water heate |

| 1 | cold water storage cistern (cover omitted for clarity) |
| 2 | warning pipe |
| 3 | vent pipe |
| 4 | hot water cylinder |
| 5 | alternative cistern fed cold supply to sanitary appliances |
| 6 | to boiler |
| 7 | mains supply pipe (Supply pressures up to 10 bar) |
EN 1113:2008+A1:2011