1 Scope
This Technical Specification is applicable to high voltage (HV) bushings, intended
for use in traction transformers of rail vehicles, cooled by insulating liquid with
rated voltages up to 25 kV single phase and rated currents up to 630 A at frequencies
from 16,7 Hz to 60 Hz.
HV bushings within the scope of this Technical Specification are bushings for separable connectors
that connect the power supply coming from a contact wire or from a contact rail to
the primary winding of the traction transformer. The Technical Specification only
deals with HV bushings that are mounted to the transformer.
CLC/TS 50537‑1
gives consideration to both technical and normative requirements of the railway environment
and restricts the variety provided by industry-wide standards for bushings, such as
EN 50180 and EN 60137. It determines requirements and tests enabling the interchangeability especially
regarding electrical and mechanical interfaces. Furthermore, service conditions are
described.
The cable plug as the counterpart of the HV bushing’s plug-in end is not covered by this Technical Specification.