1 Scope
EN 50288‑2‑2
is a sectional specification for screened cables, characterised from 1 MHz up to
100 MHz, to be used as work area cables to connect a telecommunications outlet to
the terminal equipment and for patch cord cables to establish connections on a patch
panel as defined in EN 50173. Work area and data centres cables may also be used as patch cord cables in any distributor
of a generic building wiring system to interconnect with equipment or to cross-connect
between cabling systems
This sectional specification contains the electrical, mechanical, transmission and
environmental performance characteristics of the cables, when tested in accordance
with the referenced test methods.
This sectional specification is to be read in conjunction with EN 50288‑1 which contains the essential provisions for its application.
The cables covered in this sectional specification are intended to operate with voltages
and currents normally encountered in communication systems. These cables are not intended
to be used in conjunction with low impedance sources, for example, the electric power
supplies of public utility mains.