BS 5173-103.6 describes a method of test which is primarily applicable to gas cutting and welding and similar hoses to determine the ignitability of the lining.
NOTE 1 For the purpose of this test, ignition is the initiation of combustion, which is the destruction by oxidation with the production of heat, usually with incandescence or flame, or both.
NOTE 2 The titles of the publications referred to in this standard are listed on the inside back page.
BS 5173-103.6 on ignitability of lining of rubber and plastic hoses and hoses assemblies is for:
Rubber hoses are designed for specific fluid, temperature, and pressure ranges and are provided with various specifications.
BS 5173-103.6 provides you with methods and test procedures for determining the ignitability of linings of hoses and hose assemblies that helps you to check whether they will withstand the differential pressure encountered in service resulting from reduced pressure within the hose or hose assembly.
The test methodologies given in BS 5173-103.6 enable you to examine the hose for any signs of deformation or delamination of reinforcement or lining, which contributes a lot in maintaining the high quality and efficient functioning of rubber, plastic hose, and hoses assemblies.