1 Scope
This document provides guidance on estimating the flowrate when using pressure differential
devices constructed or operated outside the scope of ISO 5167 series.
Additional tolerances or corrections cannot necessarily compensate for the effects
of deviating from ISO 5167 series. The information is given, in the first place, to indicate the degree of care necessary
in the manufacture, installation and maintenance of pressure differential devices
by describing some of the effects of non-conformity to the requirements; and in the
second place, to permit those users who cannot comply fully with the requirements
to assess, however roughly, the magnitude and direction of the resulting error in
flowrate.
Each variation dealt with is treated as though it were the only one present. Where
more than one is known to exist, there might be unpredictable interactions and care
has to be taken when combining the assessment of these errors. If there is a significant
number of errors, means of eliminating some of them have to be considered. The variations
included in this document are by no means complete and relate largely to examples
with orifice plates. An example with Venturi tubes has been placed at the end of its
section. This document does not apply to cone meters or wedge meters. There are, no
doubt, many similar examples of installations not conforming to ISO 5167 series for which no comparable data have been published. Such additional information from
users, manufacturers and any others can be taken into account in future revisions
of this document.