BS EN 50174-3 specifies requirements and provides recommendations for the following aspects of information technology cabling:
BS EN 50174-3 is applicable to all types of information technology cabling outside buildings including generic cabling systems designed in accordance with EN 50173 series. The requirements and recommendations of BS EN 50174-3 may be applied to cabling that is defined as part of the building.
The requirements and recommendations of Clauses 4, 5 and 6 of BS EN 50174-3 are subject to any site-specific requirements and recommendations of Clause 7.
The planning of the pathway systems, spaces and structures within the core and access network cabling as described in Figure 2 that are owned by access providers is excluded except for requirements and recommendations that provide basic safety, function and environmental objectives for mechanical, ingress and climatic characteristics (i.e. excluding pathway dimensions, distribution of spaces and similar constraints based on specific transmission methods).
The installation practices applicable to all cabling installation methods are included by the provision of the necessary planning requirements and recommendations associated with each one with the exception of information technology cabling installed:
This European Standard BS EN 50174-3:
BS EN 50174-3 is applicable to certain hazardous environments. It does not exclude additional requirements which are applicable in particular circumstances, defined by e.g. electricity supply and electrified railways.
Note: The requirements within BS EN 50174-3 do not cover any additional requirements for the information technology cables installed in hazardous or stressful environments e.g. electricity supply and electric railway locations (see Clause 7).
BS EN 50174-3 on Cabling installation planning and practices outside buildings is useful for:
The importance of services delivered by information technology cabling infrastructure is similar to that of utilities such as heating, lighting and electricity supplies. As with those utilities, interruptions to service can have a serious impact. Poor quality of service due to lack of planning, use of inappropriate components, incorrect installation, poor administration or inadequate support can threaten an organization’s effectiveness.
BS EN 50174-3, provides requirements and recommendations relating to the installation planning and practices which are useful to derive:
BS EN 50174-3:2013+A1:2017supersedes EN 50174-3:2003. BS EN 50174-3:2013+A1:2017 contains some technical changes as follows: