This document specifies test methods applicable to fibre-reinforced polymer (FRP) bars as reinforcement or pre-stressing tendons in concrete, including physical, mechanical, durability, and long-term properties.
FRP bars in this document are made of fibre and resin matrix. Types of fibres are aramid fibre, basalt fibre, carbon fibre or glass fibre. The matrix includes thermosetting resins, such as vinylester, unsaturated polyester resins, as well as thermoplastic resins, including polypropylene, polyamides, and polymethyl methacrylate.
BSI recommends this version of standard for organisations operating in or with the UK. The ISO edition is available here if required.