BS EN 61755-3-32 is a safety standard on fibre optic interconnecting devices and passive components.
BS EN 61755-3-32 defines certain dimensional limits of an angled PC rectangular thermoset (TS) ferrule optical interface to meet specific requirements for fibre-to-fibre interconnection. Ferrules made from the material specified in BS EN 61755-3-32 are suitable for use in categories C, U, E, and O as defined in IEC 61753-1.
Ferrule interface dimensions and features are contained in the IEC 61754 series, which deals with fibre optic connector interfaces.
BS EN 61755-3-32 on connector optical interfaces is relevant to:
The performance of a single-mode angled PC rectangular ferrule optical interface is determined by the accuracy with which the optical datum targets of two mating ferrules are aligned with each other.
There are three conditions affecting the alignment of the optical datum targets which are the following:
Parameters influencing the lateral and angular offset of the optical fibre axes include the following:
Parameters influencing the longitudinal offset of the optical fibre axes include the following:
BS EN 61755-3-32 defines the dimensional limits of angled PC rectangular ferrules with a single row of up to 12 fibres. The fibre centres are spaced with a nominal alignment pitch of 0,25 mm. Interface variants, which identify nominal ferrule cross-sections and applicable fibre counts.
Overall, BS EN 61755-3-32 is useful as it assists with the parameters that are systematically varied to determine the interrelationships with mating force.
EN 61755-3-32:2016
IEC 61755-3-32:2015