1 Scope
This part of IEC 61300 describes the procedure to determine the concentricity of the axis of the bore in
a non-angled ferrule with the axis of the ferrule, or in the case of non-angled ferrules
with fibre installed, to determine the concentricity of the axis of the fibre core