1 Scope
This Technical Specification specifies a method for the determination of the content
of cadmium, chromium, nickel and lead in fertilizers with inductively coupled plasma-atomic
emission spectrometry (ICP-AES) after extraction with aqua regia. Limits of quantification
are dependent on the sample matrix as well as on the instrument, but can roughly be
expected to be 0,3 mg/kg for Cd and 1 mg/kg for Cr, Ni and Pb.