Clause or subclause of IEC 60079‑0
|
IEC 60079‑0
clause application to IEC 60079‑11
|
||||
|---|---|---|---|---|---|
|
Intrinsically safe apparatus
|
Associated apparatus
|
||||
|
Ed. 5.0 (2007) (informative)
|
Ed. 6.0 (2011) (informative)
|
Clause / Subclause title (normative)
|
Group I and Group II
|
Group III
|
|
| 1 | 1 | Scope | Applies | Applies | Applies |
| 2 | 2 | Normative references | Applies | Applies | Applies |
| 3 | 3 | Terms and definitions | Applies | Applies | Applies |
| 4 | 4 | Equipment grouping | Applies | Applies | Applies |
| 4.1 | 4.1 | Group I | Applies | Excluded | Applies |
| 4.2 | 4.2 | Group II | Applies | Excluded | Applies |
| 4.3 | 4.3 | Group III | Excluded | Applies | Applies |
| 4.4 | 4.4 | Equipment for a particular explosive atmosphere | Applies | Applies | Applies |
| 5.1 | 5.1 | Environmental influences | Applies | Applies | Applies |
| 5.1.1 | 5.1.1 | Ambient temperature | Applies | Applies | Applies |
| 5.1.2 | 5.1.2 | External source of heating or cooling | Applies | Applies | Applies |
| 5.2 | 5.2 | Service temperature | Applies | Applies | Applies |
| 5.3.1 | 5.3.1 | Determination of maximum surface temperature | Applies | Applies | Excluded |
| 5.3.2.1 | 5.3.2.1 | Group I electrical equipment | Applies | Excluded | Excluded |
| 5.3.2.2 | 5.3.2.2 | Group II electrical equipment | Applies | Excluded | Excluded |
| 5.3.2.3 | 5.3.2.3 | Group III electrical equipment | Excluded | Applies | Excluded |
| 5.3.3 | 5.3.3 | Small component temperature for Group I or Group II electrical equipment | Applies | Excluded | Excluded |
| 6.1 | 6.1 | General | Applies | Applies | Applies |
| 6.2 | 6.2 | Mechanical strength of equipment | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 6.3 | 6.3 | Opening times | Excluded | Excluded | Excluded |
| 6.4 | 6.4 | Circulating currents in enclosures (e.g. of large electrical machines) | Excluded | Excluded | Excluded |
| 6.5 | 6.5 | Gasket retention | Excluded except when 6.1.2.3a)is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 6.6 | 6.6 | Electromagnetic and ultrasonic radiating equipment | Applies | Applies | Excluded |
| 7.1.1 | 7.1.1 | Applicability | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 7.1.2 | 7.1.2.1 | Specification of materials | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 7.1.3 | 7.1.2.2 | Plastic materials | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 7.1.4 | 7.1.2.3 | Elastomers | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 7.2 | 7.2 | Thermal endurance | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 7.3 | 7.3 | Resistance to light | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 7.4 | 7.4 | Electrostatic charges on external non-metallic materials | Applies | Applies | Excluded |
| NR | 7.5 | Accessible metal parts | Applies | Applies | Excluded |
| 7.5 | NR | Threaded holes | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 8.1 | 8.1 | Material composition | Applies | Applies | Excluded |
| 8.1.1 | 8.2 | Group I | Applies | Excluded | Excluded |
| 8.1.2 | 8.3 | Group II | Applies | Excluded | Excluded |
| 8.1.3 | 8.4 | Group III | Excluded | Applies | Excluded |
| 8.2 | NR | Threaded holes | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 9 | 9 | Fasteners | Excluded | Excluded | Excluded |
| 10 | 10 | Interlocking devices | Excluded | Excluded | Excluded |
| 11 | 11 | Bushings | Excluded | Excluded | Excluded |
| 12 | 12 | Materials used for cementing | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 13 | 13 | Ex Components | Applies | Applies | Applies |
| 14 | 14 | Connection facilities and termination compartments | Excluded | Excluded | Excluded |
| 15 | 15 | Connection facilities for earthing or bonding conductors | Excluded | Excluded | Excluded |
| 16 | 16 | Entries into enclosures | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 17 | 17 | Supplementary requirements for rotating machines | Excluded | Excluded | Excluded |
| 18 | 18 | Supplementary requirements for switchgear | Excluded | Excluded | Excluded |
| 19 | 19 | Supplementary requirements for fuses | Excluded | Excluded | Excluded |
| 20 | 20 | Supplementary requirements for plugs, socket outlets and connectors | Excluded | Excluded | Excluded |
| 21 | 21 | Supplementary requirements for luminaires | Excluded | Excluded | Excluded |
| 22 | 22 | Supplementary requirements for caplights and handlights | Modified | Modified | Excluded |
| 23.1 | 23.1 | General | Applies | Applies | Applies |
| 23.2 | 23.2 | Batteries | Excluded | Excluded | Excluded |
| 23.3 | 23.3 | Cell types | Applies | Applies | Applies |
| 23.4 | 23.4 | Cells in a battery | Applies | Applies | Applies |
| 23.5 | 23.5 | Ratings of batteries | Applies | Applies | Applies |
| 23.6 | 23.6 | Interchangeability | Applies | Applies | Applies |
| 23.7 | 23.7 | Charging of primary batteries | Applies | Applies | Applies |
| 23.8 | 23.8 | Leakage | Applies | Applies | Applies |
| 23.9 | 23.9 | Connections | Applies | Applies | Applies |
| 23.10 | 23.10 | Orientation | Applies | Applies | Applies |
| 23.11 | 23.11 | Replacement of cells or batteries | Applies | Applies | Applies |
| 23.12 | 23.12 | Replaceable battery pack | Applies | Applies | Applies |
| 24 | 24 | Documentation | Applies | Applies | Applies |
| 25 | 25 | Compliance of prototype or sample with documents | Applies | Applies | Applies |
| 26.1 | 26.1 | General | Applies | Applies | Applies |
| 26.2 | 26.2 | Test configuration | Applies | Applies | Applies |
| 26.3 | 26.3 | Tests in explosive test mixtures | Applies | Applies | Applies |
| 26.4.1 | 26.4.1 | Order of tests | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 26.4.1.1 | 26.4.1.1 | Metallic enclosures, metallic parts of enclosures and glass parts of enclosures | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 26.4.1.2 | 26.4.1.2 | Non-metallic enclosures or non-metallic parts of enclosures | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 26.4.1.2.1 | 26.4.1.2.1 | Group I electrical equipment | Excluded except when 6.1.2.3a) is applied | Excluded | Excluded except when 6.1.2.3a) is applied |
| 26.4.1.2.2 | 26.4.1.2.2 | Group II and Group III electrical equipment | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 26.4.2 | 26.4.2 | Resistance to impact | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 26.4.3 | 26.4.3 | Drop test | Applies | Applies | Excluded except when 6.1.2.3a) is applied |
| 26.4.4 | 26.4.4 | Acceptance criteria | Applies | Applies | Excluded except when 6.1.2.3a) is applied |
| 26.4.5 | 26.4.5 | Degree of protection (IP) by enclosures | Applies | Applies | Applies |
| 26.5.1.1 | 26.5.1.1 | General | Applies | Applies | Excluded |
| 26.5.1.2 | 26.5.1.2 | Service temperature | Modified | Modified | Modified |
| 26.5.1.3 | 26.5.1.3 | Maximum surface temperature | Modified | Modified | Modified |
| 26.5.2 | 26.5.2 | Thermal shock test | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 26.5.3 | 26.5.3 | Small component ignition test (Group I and Group II) | Applies | Excluded | Excluded |
| 26.6 | 26.6 | Torque test for bushings | Excluded | Excluded | Excluded |
| 26.7 | 26.7 | Non-metallic enclosures or non-metallic parts of enclosures | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 26.8 | 26.8 | Thermal endurance to heat | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 26.9 | 26.9 | Thermal endurance to cold | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 26.10 | 26.10 | Resistance to light | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 26.11 | 26.11 | Resistance to chemical agents for Group I electrical equipment | Excluded except when 6.1.2.3a) is applied | Excluded | Excluded |
| 26.12 | 26.12 | Earth continuity | Excluded | Excluded | Excluded |
| 26.13 | 26.13 | Surface resistance test of parts of enclosures of non-metallic materials | Applies | Applies | Excluded |
| 26.15 | 26.14 | Measurement of capacitance | Applies | Applies | Excluded |
| NR | 26.15 | Verification of ratings of ventilating fans | Excluded | Excluded | Excluded |
| NR | 26.16 | Alternative qualification of elastomeric sealing O-rings | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
| 27 | 27 | Routine tests | Applies | Applies | Applies |
| 28 | 28 | Manufacturer’s responsibility | Applies | Applies | Applies |
| 29 | 29 | Marking | Applies | Applies | Applies |
| 30 | 30 | Instructions | Applies | Applies | Applies |
| Annex A (Normative) | Annex A (Normative) | Supplementary requirements for cable glands | Excluded | Excluded | Excluded |
| Annex B (Normative) | Annex B (Normative) | Requirements for Ex Components | Applies | Applies | Applies |
| Annex C (Informative) | Annex C (Informative) | Example of rig for resistance to impact test | Applies | Applies | Excluded except when 6.1.2.3a) is applied |
| Annex D (Informative) | NR | Alternative risk assessment method encompassing “equipment protection levels” for Ex equipment | Applies | Applies | Applies |
| Annex E (Informative) | Annex D (Informative) | Motors supplied by converters | Excluded | Excluded | Excluded |
| NR | Annex E (Informative) | Temperature rise testing of electric machines | Excluded | Excluded | Excluded |
| NR | Annex F (Informative) | Guideline flowchart for tests of non-metallic enclosures or non-metallic parts of enclosures (26.4) | Excluded except when 6.1.2.3a) is applied | Excluded except when 6.1.3 a) is applied. | Excluded except when 6.1.2.3a) is applied |
|
Applies – This requirement of IEC 60079‑0 is applied without change.
Excluded – This requirement of IEC 60079‑0 does not apply.
Excluded except – This requirement of IEC 60079‑0 does not apply except when the conditions stated are met.
Modified – This requirement of IEC 60079‑0 is modified as detailed in this standard.
NR – No requirements.
|
|||||
|
NOTE The clause numbers in the above table are shown for information only. The applicable requirements of IEC 60079‑0 are identified by the clause title which is normative. This table was written against the specific requirements of IEC 60079‑0, ed. 6.0. The clause numbers for the previous edition are shown for information only. This is to enable the General requirements IEC 60079‑0, ed. 5.0, to be used where necessary with this part of IEC 60079. Where there were no requirements, indicated by NR, or there is a conflict between requirements, the later edition requirements take precedence. |
|||||
IEC 60079-11:2011/ISH1:2014