What is BS EN IEC 60079-14 - Explosive atmospheres electrical installation about?
The sixth and latest edition of this best-selling international standard, BS EN IEC 60079-14:2024 recommends protective measures that reduce to an acceptable level the likelihood that an electrical installation can become a source of ignition in or near an explosive atmosphere.
Who is BS EN IEC 60079-14 - Explosive atmospheres electrical installation for?
- Users of this standard include:
- manufacturers of electrical equipment used in hazardous environments;
- engineers and designers;
- safety inspectors; and
- industrial facilities such as offshore rigs, oil refineries, chemical plants.
What does BS EN IEC 60079-14 - Explosive atmospheres electrical installation cover?
It specifies requirements for the design of electrical systems, selection, installation and the required initial inspection of electrical installations of Ex Equipment in, or associated with, explosive atmospheres including requirements for documentation and personnel competency.
These requirements are in addition to the requirements for installations in non-hazardous areas.
BS EN IEC 60079-14:2024 applies to all electrical Ex Equipment including fixed, transportable, portable and personal, and installations, permanent or temporary.
Why should you use BS EN IEC 60079-14 - Explosive atmospheres electrical installation?
-
Safety: BS EN IEC 60079-14 details internationally agreed measures that minimize potential ignition sources in electrical installations in extremely hazardous environments, helping prevent fires and explosions as well as equipment failure, and ensuring better protection for workers and the environment.
-
Compliance: BS EN IEC 60079-14 helps users comply with the latest regulatory safety requirements, plus staying compliant helps avoid legal complications and penalties and improves workplace morale.
-
Risk management: By increasing knowledge and expertise in the area of design and installation, BS EN IEC 60079-14 minimizes risks, and helps ensure that employers and organizations exercise the necessary duty of care.
-
Efficiency: BS EN IEC 60079-14 helps users optimize the design, engineering, and installation of electrical equipment in hazardous areas. In addition, greater safety means there’s less downtime and so increased productivity.
-
Currency: The newest version contains a number of significant technical updates that will improve the reliability and efficiency of equipment installations in hazardous environments.
Increase the safety of your industrial installations using the newly revised BS EN IEC 60079-14:2024 Explosive atmospheres – Part 14: Electrical installation design, selection and installation of equipment, including initial inspection.
What is new on BS EN IEC 60079-14 - Explosive atmospheres electrical installation?
This is the first revision of this standard in ten years. It introduces significant technical updates that improve the document's clarity and can increase the reliability and efficiency of installations.
Changes to the standard include:
- a new flowchart for selection of cable entry devices;
- a new informative annex on initial inspection tables;
- a new normative annex on pressure test procedure for cables;
- changed cable requirements;
- changed use of adapters and reducers;
The BS EN IEC edition includes a National Annex providing further essential guidance to assist users in the application of the standard, particularly alongside BS 7671 Requirements for Electrical Installations, and BS 7430 Protective earthing of electrical installations. Code of practice. As such, there is useful additional information covering Clauses relating to ‘Power supply systems to hazardous area installations’ (including TN-S); ‘Design’ (including earthing and equipotential bonding systems); ‘Installation’, ‘Inspection’ and ‘EMC requirements’ amongst others.