1 Scope and object
This part of IEC 60512, when required by the detail specification, is used for testing connectors within
the scope of technical committee 48. It may also be used for similar devices when
specified in a detail specification.
The object of this standard is to detail a standard test method to determine the value
of RF shunt resistance which degrades the quality factor of an L/C circuit when a
connector is connected in parallel. This value is expressed in terms of a parallel
damping resistance.