1 Scope
This document describes calculation models to estimate the sound pressure level in
buildings due to service equipment. As for the field measurement document (EN ISO 16032) it covers sanitary installations, mechanical ventilation, heating and cooling, service
equipment, lifts, rubbish chutes, boilers, blowers, pumps and other auxiliary service
equipment, and motor driven car park doors, but can also be applied to others equipment
attached to or installed in buildings. The estimation is primarily based on measured
data that characterises both the sources and the building constructions. The models
given are applicable to calculations in frequency bands.
This document describes the principles of the calculation models, lists the relevant
quantities and defines its applications and restrictions. It is intended for acoustical
experts and provides the framework for the development of application documents and
tools for other users in the field of building construction, taking into account local
circumstances.
The calculation models described use the most general approach for engineering purposes,
with a link to measurable quantities that specify the performance of building elements
and equipment. The known limitations of these calculation models are described in
this document. Users should, however, be aware that other calculation models also
exist, each with their own applicability and restrictions.
The models are based on experience with predictions for dwellings and offices; they
could also be used for other types of buildings provided the constructional dimensions
are similar to those in dwellings.