NOTE 1 Issues of binaural calculations are discussed in Annex A.
NOTE 2 Users who wish to study the details of the calculation method can review or implement the source code, which is entirely informative and provided with this document for the convenience of the user.
NOTE 3 It has been shown (see Reference [15]) that this method provides a good match to the contours of equal loudness level as defined in ISO 226:2003 and the reference threshold of hearing as defined in ISO 389‑7:2005.
BSI recommends this version of standard for organisations operating in or with the UK. The ISO edition is available here if required.