BS 6400 is a series of three standards consisting of the following parts:
BS 6400-2:2006 specifies the requirements for the installation, exchange, relocation and removal of primary meters with a maximum capacity of 6 m³/h. It is applicable to installations that incorporate credit or prepayment diaphragm and ultrasonic gas meters with a capacity of 6 m³/h.
For the purposes of this standard, installation includes design, inspection and commissioning. It is recognised that each of these tasks can be performed by the same person. This standard applies to primary meter installations:
Installation, exchange, relocation and removal of a secondary meter with a maximum capacity of 6 m³/h is specified in BS 6400-1.
For installation pipework is please refer to BS 6891.
Service pipes (including the emergency control valve) are specified in the Institution of Gas Engineers and Managers’ publication on gas services, IGE/TD/4.
All pressures quoted in this standard are gauge pressures and all pressure absorption values are for natural gas unless otherwise specified.
Additional guidance on domestic gas systems can be found in the European functional standards BS EN 1775 and BS EN 12279.
BS 6400-2:2006 supersedes BS 6400:1997 which is now withdrawn.